Computer Controlled System for Impedance Measurements

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F19%3APU135994" target="_blank" >RIV/00216305:26310/19:PU135994 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/8810296/authors#authors" target="_blank" >https://ieeexplore.ieee.org/document/8810296/authors#authors</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/ISSE.2019.8810296" target="_blank" >10.1109/ISSE.2019.8810296</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Computer Controlled System for Impedance Measurements

  • Original language description

    Setup for impedance measurement based on AD5933 impedance convertor was accomplished and tested with a measurement of control samples. Introducing an external clock generator allows to extend the excitation frequencies in the range of 1 00 Hz÷50 KHz. An external analog front end schematics was added to reduce the output impedance and facilitate the measurement. The external analog front end includes low pass filter, voltage follower and current to voltage convertor. The measurement performed is in a good agreement with data taken from control impedance analyzer. The noise and signal distortion is considerable reduced using galvanic insulation between the personal computer and microcontroller from one side and the AD5933 impedance converter and the analog front end from the other. The relative error with respect to reference calibration resistors is within the range of ±0.5 %. A stability test shows that the change of the impedance with the time is less than 10 %, measured over 60 hours. A measurement of ionic liquid used as a simplified biomedical impedance model is with a good compliance with data, taken from a precise impedance analyzer.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/LO1211" target="_blank" >LO1211: Materials Research Centre at FCH BUT- Sustainability and Development</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the International Spring Seminar on Electronics Technology

  • ISBN

    978-1-7281-1874-1

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    1-5

  • Publisher name

    IEEE

  • Place of publication

    Wroclaw, Poland

  • Event location

    Wroclaw, Poland

  • Event date

    May 15, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000507501000068