Critical Weak Points of Atmospheric Plasma Sprayed Thermal Barrier Coatings
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F13%3APU104561" target="_blank" >RIV/00216305:26620/13:PU104561 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Critical Weak Points of Atmospheric Plasma Sprayed Thermal Barrier Coatings
Original language description
The 8 wt. % yttria stabilized zirconia top coat (TC) and the CoNiCrAlY bond coat (BC) were sprayed onto the surface of newly developed fine-grained cast polycrystalline nickel-based superalloy Inconel 713LC by means of atmospheric plasma spraying (APS). As-prepared samples were isothermally exposed at the temperature of 1050 C for 200 hours in an ambient atmosphere. Structural changes in the thermal barrier coatings (TBC) system after thermal exposure were studied by means of scanning electron microscope equipped with an energy dispersive microanalyzer. Critical weak points were identified on both the substrate-bond coat and bond coat-top coat interfaces.