Investigating the effects of laser wavelengths and other ablation parameters on the detection of biogenic elements and contaminants in hydroxyapatite
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F24%3APU152406" target="_blank" >RIV/00216305:26620/24:PU152406 - isvavai.cz</a>
Result on the web
<a href="https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00073k" target="_blank" >https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00073k</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/d4ja00073k" target="_blank" >10.1039/d4ja00073k</a>
Alternative languages
Result language
angličtina
Original language name
Investigating the effects of laser wavelengths and other ablation parameters on the detection of biogenic elements and contaminants in hydroxyapatite
Original language description
The main purpose of this work is to thoroughly describe sensitivity and resolution enhancement by systematically optimizing key parameters in laser-induced breakdown spectroscopy analysis. Simultaneous analysis of biogenic (C, P, Mg, and Ca) and contaminating (Pb) elements, which are commonly detected in selected biotic matrices (mammal teeth), was performed. Hydroxyapatite reference pellets were utilized as model matrices, which successfully reflect human dental tissue. The optimization involved precise adjustments of the used laser wavelengths (1064, 532, and 266 nm), relative defocus of the laser pulse, ablation pulse energies, and gate delays for collecting characteristic spectra. In addition, for Ca analysis, the signals of different ionization line types (Ca I 364.44 nm; Ca II 370.60 and 396.85 nm) were compared; in the case of Pb analysis, the limits of detection were established for each used laser wavelength, and the revealed differences were discussed in detail. We intend to demonstrate the benefits of rapid, low-cost analysis and also the importance of measurement parameters used in biotic sample testing. A comparison of laser ablation measurement parameters (laser wavelength, energy, gate delay, defocus, and spot size) to determine optimal settings for the detection of heavy metals and biogenic elements in a hard tissue matrix (hydroxyapatite).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Analalytical Atomic Spectrometry
ISSN
0267-9477
e-ISSN
1364-5544
Volume of the periodical
39
Issue of the periodical within the volume
9
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
2330-2339
UT code for WoS article
001285048500001