All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Verification of reliability of measurement systems for swimming analysis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26630%2F21%3APU142449" target="_blank" >RIV/00216305:26630/21:PU142449 - isvavai.cz</a>

  • Alternative codes found

    RIV/61989592:15510/21:73612338

  • Result on the web

    <a href="https://rua.ua.es/dspace/bitstream/10045/113666/1/JHSE_16_Proc2_52.pdf" target="_blank" >https://rua.ua.es/dspace/bitstream/10045/113666/1/JHSE_16_Proc2_52.pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.14198/jhse.2021.16.Proc2.52" target="_blank" >10.14198/jhse.2021.16.Proc2.52</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Verification of reliability of measurement systems for swimming analysis

  • Original language description

    Sophisticated technologies and measuring devices are increasingly being used for the analysis of performance and swimming techniques. At BUT, the Tachograph II and Swimming Inertial Measure Unit (SwIMU) measuring systems were developed for swimming analysis. To evaluate the measured data, the SwimDataViewer software was developed for both measuring systems. To verify the reliability of the Tachograph, 34 race swimmers were measured (15 F, 19 M), and 28 race swimmers (16 M, 12 F) were measured with SwIMU. All swimmers swam a 6x25m front crawl. Pullout and the first three and last two strokes of the arms were not included in the data evaluation. The intraclass correlation coefficient (ICC) was used to verify the reliability of the monitored parameters. The values of measured parameters in the front crawl for Tachograph (SwIMU) were ICC = 0.992 (0.991) for the average value of speed, ICC = 0.958 (0.960) for efficiency, ICC = 0.971 (0.988) for the frequency of the arms, and finally, ICC = 0.978 (0.992) for the frequency of the legs. The ICC coefficient for all monitored parameters in both devices showed a high degree of reliability. From this perspective, both devices are suitable for use in coaching and research practice.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30306 - Sport and fitness sciences

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Human Sport and Exercise

  • ISSN

    1988-5202

  • e-ISSN

  • Volume of the periodical

    16

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    ES - SPAIN

  • Number of pages

    7

  • Pages from-to

    „S671“-„S677“

  • UT code for WoS article

    000681300500052

  • EID of the result in the Scopus database

    2-s2.0-85114730450