Comparison of LCP and intramedullary nail osteosynthesis in calcaneal fractures
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F19%3A10404610" target="_blank" >RIV/00669806:_____/19:10404610 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/19:10404610
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=7G5DnXxMRc" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=7G5DnXxMRc</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1590/1413-785220192706223193" target="_blank" >10.1590/1413-785220192706223193</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of LCP and intramedullary nail osteosynthesis in calcaneal fractures
Original language description
Objective: This study compared groups of patients with calcaneal fractures of Sanders types II and III. One group was treated with ORIF using an LCP (plate), while the second was treated with a minimally invasive method using a C-Nail. Methods: The study included 217 patients in the ORIF group and 19 patients in the minimally invasive nail osteosynthesis group. Results: In the LCP group, the outcomes were excellent for 35.7% of the patients; good, 38.9%; satisfactory, 19.7%; and poor, 5.7%. In the C-Nail group, the outcomes were excellent for 36.9% of the patients; good; 31.6%; satisfactory, 21%; and poor, 10.2%. The mean values of the restoration of Bohler's angle from post-injury were 6.8 degrees to 32.3 degrees in the LOP group and 7.1 degrees to 33.3 degrees in the C-Nail group. After 12 months, there was only a minimal decrease in Bohler's angle to 29.2 degrees in both the LCP and C-Nail groups. Conclusion: The outcomes obtained with C-Nail fixation are statistically identical to those obtained with LCP fixation. We conclude that osteosynthesis with a C-Nail is suitable as the first-choice treatment for Sanders types II and III fractures.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Ortopedica Brasileira
ISSN
1413-7852
e-ISSN
—
Volume of the periodical
27
Issue of the periodical within the volume
6
Country of publishing house
BR - BRAZIL
Number of pages
6
Pages from-to
288-293
UT code for WoS article
000494948000001
EID of the result in the Scopus database
2-s2.0-85076319286