Unattended automated office blood pressure measurement in children
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F21%3A10432316" target="_blank" >RIV/00669806:_____/21:10432316 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/21:10432316 RIV/00064203:_____/21:10432316 RIV/00216208:11130/21:10432316 RIV/00216208:11130/23:10459046 and 2 more
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Q5wLja9X0Y" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Q5wLja9X0Y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/08037051.2021.1963666" target="_blank" >10.1080/08037051.2021.1963666</a>
Alternative languages
Result language
angličtina
Original language name
Unattended automated office blood pressure measurement in children
Original language description
PURPOSE: We studied the performance of unattended automated office blood pressure (uAOBP) measurement in children, in relation to oscillometric office BP (OBP) and ambulatory blood pressure monitoring (ABPM). MATERIALS AND METHODS: One hundred and eleven stable treated and untreated outpatients investigated for hypertension underwent uAOBP measurements (seated unattended in a quiet room separate from the renal clinic room, six times after a 5 min rest with the BpTRU device), and immediately before using the oscillometric device. Ambulatory 24 h blood pressure monitoring (ABPM) was performed on the same day in a subgroup of 42 children. RESULTS: UAOBP measurements were successful in 106 children (95%), 5 pre-school children did not tolerate to be alone in the room. The mean +- SD systolic/diastolic uAOBP, OBP and daytime ABP were 109.1 +- 14.0/70.8 +- 10.7 mmHg, 121.6 +- 16.5/77.6 +- 10.5 mmHg and 123.5 +- 11.3/73.7 +- 6.8 mmHg, respectively. Systolic/diastolic uAOBP was significantly lower than OBP by 13.6/7.6 mmHg (p < 0.0001) and lower than daytime ABP by 14.4 +- 0.5/2.9 +- 0.3 mmHg (p < 0.0001). The heart rate was not significantly different during uAOBP than during OBP measurements. On Bland Altman analysis the uAOBP underestimated OBP by a mean of 15.6 mmHg for systolic BP and by 8.6 mmHg for diastolic BP. In all 9 children with white-coat systolic hypertension uAOBP was within the normal range (<95th pc for OBP), in six of nine children with white-coat diastolic hypertension uAOBP was within the normal range however, in three of them it was elevated despite normal ABP. CONCLUSION: uAOBP measurement is feasible in school-aged children, its values are considerably lower than OBP as well as daytime ABP and it could help with detection of white-coat systolic hypertension. The clinical applicability of uAOBP in children should be confirmed in further studies.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30209 - Paediatrics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Blood Pressure
ISSN
0803-7051
e-ISSN
—
Volume of the periodical
30
Issue of the periodical within the volume
6
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
359-366
UT code for WoS article
000700672300001
EID of the result in the Scopus database
2-s2.0-85115671723