One-Step Nucleic Acid Amplification Analysis of Sentinel Lymphatic Nodes in Endometrial Cancer Patients (EU-OSNA): A European Multicenter Diagnostic Accuracy Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F25%3A10503309" target="_blank" >RIV/00669806:_____/25:10503309 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/25:10503309
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=YezvGb_rg-" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=YezvGb_rg-</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/cam4.71268" target="_blank" >10.1002/cam4.71268</a>
Alternative languages
Result language
angličtina
Original language name
One-Step Nucleic Acid Amplification Analysis of Sentinel Lymphatic Nodes in Endometrial Cancer Patients (EU-OSNA): A European Multicenter Diagnostic Accuracy Study
Original language description
OBJECTIVE: This European multicenter study aimed to assess the diagnostic accuracy of one-step nucleic acid amplification (OSNA) as the primary endpoint by comparing this method with ultrastaging for the detection of sentinel node metastases in endometrial cancer patients. METHODS: European multicenter prospective performance study including data from 10 centers across 5 European countries. Each node, upon removal of surrounding adipose tissue, was sliced in 2 mm thick sections and equally distributed between ultrastaging and OSNA. OSNA is based on cytokeratin-19 detection, serving as a metastatic marker. Sensitivity, specificity, and concordance of OSNA versus ultrastaging were calculated at nodal and patient levels. RESULTS: Seven hundred forty-three sentinel nodes from 366 patients were evaluated. Compared to ultrastaging, OSNA showed concordance, specificity, and sensitivity of 95%, 97.6%, and 41.2% at the nodal level and 93.2%, 96.2%, and 47.8% at the patient level, respectively. In reverse analysis, when compared to OSNA, the ultrastaging showed a sensitivity of 45.2% and 45.8% at the nodal and patient levels, respectively. Irrespective of the size of metastasis, both methods agreed in 14 positive and 692 negative nodes (95%). This resulted in 24 (6.56%) patients with a positive OSNA and 23 (6.28%) patients with a positive ultrastaging finding. The number of discordant nodes was 47 (6.33%), 40 (85.1%) of them were micrometastases. Benign epithelial inclusions occurred in 4 nodes (0.54%) and 4 patients (1.09%). CONCLUSION: Compared with ultrastaging, OSNA showed high concordance and specificity, but sensitivity was low-similar to ultrastaging compared with OSNA as an index test in reverse analysis. The main limitation in comparing the two approaches by splitting the sentinel nodes was the tissue allocation bias. As reflected in the number of discordant cases, especially at the micrometastases level. The distribution of patients with node metastases was comparable between the two methods at both the nodal and patient levels. TRIAL REGISTRATION: German Clinical Trial Register: Nr. DRKS00021520.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30214 - Obstetrics and gynaecology
Result continuities
Project
<a href="/en/project/LX22NPO5102" target="_blank" >LX22NPO5102: National institute for cancer research</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cancer Medicine
ISSN
2045-7634
e-ISSN
2045-7634
Volume of the periodical
14
Issue of the periodical within the volume
18
Country of publishing house
GB - UNITED KINGDOM
Number of pages
11
Pages from-to
e71268
UT code for WoS article
001576625100001
EID of the result in the Scopus database
2-s2.0-105016754198