Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F12%3A00102800" target="_blank" >RIV/00843989:_____/12:00102800 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers
Original language description
Objectives-Ultrasound has various biological effects in the human body. The effects of continuous monitoring with ultrasound (sonolysis) on vasodilatation of the radial artery were described recently. We wanted to ascertain whether similar changes in theblood flow velocity during sonolysis could also be detected in the middle cerebral artery. Methods-Fifteen healthy volunteers (6 male and 9 female; age range, 23-68 years; mean +/- SD, 47.1 +/- 15.1 years) were subjected to 1 hour of middle cerebral artery sonolysis using a diagnostic transcranial probe with a 2-MHz Doppler frequency and measurement of the blood flow velocity at 2-minute intervals. During a second session, a flow curve was recorded for 10 seconds at 2-minute intervals. The peak systolic velocity, end-diastolic velocity, mean flow velocity, pulsatility index, and resistive index were recorded during both measurements. Results-Irregular changes in the measured blood flow parameters were recorded during both sessions. Cha
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FH - Neurology, neuro-surgery, nuero-sciences
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/NT11386" target="_blank" >NT11386: Risk reduction of symptomatic and silent brain infarctions during carotid endarterectomy and carotid stenting due to ultrasound activation of endogenous fibrinolytic system using transcranial Doppler monitoring</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Ultrasound in Medicine
ISSN
0278-4297
e-ISSN
—
Volume of the periodical
31
Issue of the periodical within the volume
11
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
1789-1794
UT code for WoS article
000310653000012
EID of the result in the Scopus database
—