A single reference measurement can predict liver tumor motion during respiration
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F16%3AE0105514" target="_blank" >RIV/00843989:_____/16:E0105514 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.rpor.2015.11.003" target="_blank" >http://dx.doi.org/10.1016/j.rpor.2015.11.003</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.rpor.2015.11.003" target="_blank" >10.1016/j.rpor.2015.11.003</a>
Alternative languages
Result language
angličtina
Original language name
A single reference measurement can predict liver tumor motion during respiration
Original language description
Aim: To evaluate liver tumor motion and how well reference measurement predicts motion during treatment. Material and methods: This retrospective study included 20 patients with colorectal cancer that had metastasized to the liver who were treated with stereotactic ablative radiotherapy. An online respiratory tumor tracking system was used. Tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) direcitons were collected to generate patient-specific margins. Reference margins were generated as the mean motion and 95th percentile of motion from measurements recorded for different lengths of time (1, 3, and 5 min). We analyzed the predictability of tumor motion in each axis, based on the reference measurement and intra-/interfraction motions. Results: About 96,000 amplitudes were analyzed. The mean tumor motions were 9.9±4.2 mm, 2.6±0.8 mm, and 4.5±1.8 mm in the SI, LL, and AP directions, respectively. The intrafraction variations were 3.5±1.8 mm, 0.63±0.35 mm, and 1.4±0.65 mm for the SI, LL, and APdirections, respectively. The interfraction motion variations were 1.32±0.79 mm, 0.31±0.23 mm, and 0.68±0.62 mm for the SI, LL, and AP directions, respectively. The Pearson´s correlation coefficients for margins based on the reference measurement (mean motion or 95th percentile) and margins covering 95% of the motion during the whole treatment were 0.8-0.91, 0.57-0.7, and 0.77-0.82 in the SI, LL, and AP directions, respectively. Conclusion: Liver tumor motion in the SI direction can be adequately represented by the mean tumor motion amplitude generated from a single 1 min reference measurement. Longer reference measurements did not improve results for patients who were well-educated about the importance of regular breathing. Although the study was based on tumor tracking data, the results are useful for ITV delineation when tumor tracking is not available.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FD - Oncology and haematology
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Reports of practical oncology and radiotherapy
ISSN
1507-1367
e-ISSN
—
Volume of the periodical
21
Issue of the periodical within the volume
n. 3
Country of publishing house
PL - POLAND
Number of pages
6
Pages from-to
"p. 278-283"
UT code for WoS article
—
EID of the result in the Scopus database
—