Analysis of lung tumor motion in a large sample: patterns and factors influencing precise delineation of internal target volume
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F16%3AE0105651" target="_blank" >RIV/00843989:_____/16:E0105651 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.ijrobp.2016.08.008" target="_blank" >http://dx.doi.org/10.1016/j.ijrobp.2016.08.008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijrobp.2016.08.008" target="_blank" >10.1016/j.ijrobp.2016.08.008</a>
Alternative languages
Result language
angličtina
Original language name
Analysis of lung tumor motion in a large sample: patterns and factors influencing precise delineation of internal target volume
Original language description
Understanding patterns of tumor motion and involving them in treatment planning is important for performing precise lung radiation therapy. Data from online tumor tracking was used to evaluate respiratory motions of lung tumors and to describe factors affecting range of motion and motion variability during radiation therapy.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FD - Oncology and haematology
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International journal of radiation oncology, biology, physics
ISSN
0360-3016
e-ISSN
—
Volume of the periodical
96
Issue of the periodical within the volume
n. 4
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
"p. 751-758"