Design of proposed software system for prediction of iliosacral screw placement for iliosacral joint injuries based on X-ray and CT images
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F23%3AE0110227" target="_blank" >RIV/00843989:_____/23:E0110227 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27240/23:10252300 RIV/61989100:27360/23:10252300
Result on the web
<a href="https://www.mdpi.com/2077-0383/12/6/2138" target="_blank" >https://www.mdpi.com/2077-0383/12/6/2138</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jcm12062138" target="_blank" >10.3390/jcm12062138</a>
Alternative languages
Result language
angličtina
Original language name
Design of proposed software system for prediction of iliosacral screw placement for iliosacral joint injuries based on X-ray and CT images
Original language description
One of the crucial tasks for the planning of surgery of the iliosacral joint is placing an iliosacral screw with the goal of fixing broken parts of the pelvis. Tracking of proper screw trajectory is usually done in the preoperative phase by the acquisition of X-ray images under different angles, which guide the surgeons to perform surgery. This approach is standardly complicated due to the investigation of 2D X-ray images not showing spatial perspective. Therefore, in this pilot study, we propose complex software tools which are aimed at making a simulation model of reconstructed CT (DDR) images with a virtual iliosacral screw to guide the surgery process. This pilot study presents the testing for two clinical cases to reveal the initial performance and usability of this software in clinical conditions. This model is consequently used for a multiregional registration with reference intraoperative X-ray images to select the slide from the 3D dataset which best fits with reference X-ray. The proposed software solution utilizes input CT slices of the pelvis area to create a segmentation model of individual bone components. Consequently, a model of an iliosacral screw is inserted into this model. In the next step, we propose the software CT2DDR which makes DDR projections with the iliosacral screw. In the last step, we propose a multimodal registration procedure, which performs registration of a selected number of slices with reference X-ray, and based on the Structural Similarity Index (SSIM) and index of correlation, the procedure finds the best match of DDR with X-ray images. In this pilot study, we also provide a comparative analysis of the computational costs of the multimodal registration upon various numbers of DDR slices to show the complex software performance. The proposed complex model has versatile usage for modeling and surgery planning of the pelvis area in fractures of iliosacral joints.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Result continuities
Project
<a href="/en/project/EF17_049%2F0008441" target="_blank" >EF17_049/0008441: Innovative therapeutic methods of musculoskeletal system in accident surgery</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of clinical medicine
ISSN
2077-0383
e-ISSN
2077-0383
Volume of the periodical
12
Issue of the periodical within the volume
article 2138
Country of publishing house
CH - SWITZERLAND
Number of pages
17
Pages from-to
1-17
UT code for WoS article
000958032700001
EID of the result in the Scopus database
2-s2.0-85151668556