Liquid chromatography-tandem mass spectrometry for determination of fingolimod and its active metabolite fingolimod phosphate in whole blood of patients with multiple sclerosis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F24%3AE0111118" target="_blank" >RIV/00843989:_____/24:E0111118 - isvavai.cz</a>
Alternative codes found
RIV/61988987:17110/24:A2503AI8
Result on the web
<a href="https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/bmc.5947" target="_blank" >https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/bmc.5947</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/bmc.5947" target="_blank" >10.1002/bmc.5947</a>
Alternative languages
Result language
angličtina
Original language name
Liquid chromatography-tandem mass spectrometry for determination of fingolimod and its active metabolite fingolimod phosphate in whole blood of patients with multiple sclerosis
Original language description
Fingolimod is an oral drug for the escalation of treatment of relapsing-remitting multiple sclerosis in patients with persistent disease activity on first-line drugs or in patients with rapidly progressive severe relapsing-remitting multiple sclerosis. An ultra-high-performance liquid chromatography-tandem mass spectrometry method for determining the concentrations of fingolimod and its active metabolite fingolimod phosphate in whole blood has been developed and validated. The advantages of this method are the easy, fast and cheap sample preparation using protein precipitation from blood with a mixture of acetonitrile-methanol (40:60, v/v). Chromatographic separation was performed on a ultra-high performance liquid chromatography BEH C18 1.7 µm (100 × 2.1 mm) column. Two modes of ionization, electrospray ionization and atmospheric pressure chemical ionization, were tested and compared. For validation, the electrospray ionization mode was chosen. As internal standard, isotopically labeled fingolimod-D4 was used to quantify the analytes. The method was validated according to the rules of the European Medicines Agency. The coefficients of variation for fingolimod were in the range of 1.13-11.88%, and the recovery was 98.80-106.00%. The coefficients of variation for fingolimod phosphate were in the range of 2.73-9.31%, and the recovery was 90.08-107.00%. The method is quite easy and fast and can be used for routine analysis.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30104 - Pharmacology and pharmacy
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical chromatography
ISSN
0269-3879
e-ISSN
1099-0801
Volume of the periodical
38
Issue of the periodical within the volume
9
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
1-9
UT code for WoS article
001255092700001
EID of the result in the Scopus database
2-s2.0-85197280176