Tissue adhesives in the prevention of phlebitis and migration of PICC catheters in adults: a randomized prospective study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F25%3AE0111967" target="_blank" >RIV/00843989:_____/25:E0111967 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27240/25:10259614
Result on the web
<a href="https://kont.zsf.jcu.cz/pdfs/knt/2025/03/06.pdf" target="_blank" >https://kont.zsf.jcu.cz/pdfs/knt/2025/03/06.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.32725/kont.2025.030" target="_blank" >10.32725/kont.2025.030</a>
Alternative languages
Result language
angličtina
Original language name
Tissue adhesives in the prevention of phlebitis and migration of PICC catheters in adults: a randomized prospective study
Original language description
Aim: Tissue adhesives (TA) have been reported to improve the stability of various types of catheters. TA use for peripherally inserted central venous catheters (PICCs), however, remains largely unstudied. Here, we aimed to evaluate the effects of TA use on the development of phlebitis, bacterial colonization, and catheter migration in PICCs inserted in adult patients. Methods: This prospective randomized trial was conducted over a 43-month period from May 2021 to December 2024. Patients were divided into treatment group (PICC secured with TA) and control group (no TA). Signs of phlebitis (evaluated using CLISA scale) and catheter migration were recorded on Days 1 and 7. Swabs for determining bacterial colonization were taken on Day 7. Results: Of 253 patients included in the final evaluation, none developed phlebitis, although bacterial colonization was detected in 30 patients in the control group and 26 in the TA group on Day 7. Of these, however, only 4 samples contained potentially pathogenic bacteria. Migration > 20 mm occurred in < 5% of patients in both groups, minor migration < 20 mm in < 10% of patients in each group. No statistically significant differences were detected between the groups in any of the observed parameters. Conclusion: In a setting with highly trained nursing staff using an anchoring device and dressing, the additional use of TA brought no benefits to the patients.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30307 - Nursing
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Kontakt
ISSN
1212-4117
e-ISSN
1804-7122
Volume of the periodical
27
Issue of the periodical within the volume
3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
6
Pages from-to
226-231
UT code for WoS article
001589184400006
EID of the result in the Scopus database
2-s2.0-105019300190