Dynamic myocardial perfusion SPECT: Prognostic value of myocardial stress blood flow and coronary flow reserve quantification
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F25%3AE0112050" target="_blank" >RIV/00843989:_____/25:E0112050 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/25:00142121 RIV/61988987:17110/25:A2603DPY RIV/61989592:15110/25:73632853 RIV/00098892:_____/25:10159626 RIV/00159816:_____/25:00082319
Result on the web
<a href="https://journals.viamedica.pl/polish_heart_journal/article/view/108516/84739" target="_blank" >https://journals.viamedica.pl/polish_heart_journal/article/view/108516/84739</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33963/v.phj.108516" target="_blank" >10.33963/v.phj.108516</a>
Alternative languages
Result language
angličtina
Original language name
Dynamic myocardial perfusion SPECT: Prognostic value of myocardial stress blood flow and coronary flow reserve quantification
Original language description
Positron emission tomography (PET) remains the gold standard for measuring myocardial blood flow (MBF) and coronary flow reserve (CFR), but it requires an on-site cyclotron or costly generator for the production of PET perfusion tracers. In recent years, several studies have had good agreement in the calculation of MBF and CFR, confirming the feasibility and reproducibility, as well as good agreement between PET and single photon emission computed tomography (SPECT) using dedicated cadmium-zinc-telluride (CZT) tomographic 3 cameras. However, the great disadvantage of the typical dynamic SPECT protocol is its complexity, with a greater radiation burden, cost, and acquisition time. The aim of this study was to compare the prognostic significance of stress (strMBF), CFR, and assess the potential of a strMBF-only protocol.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Kardiologia Polska
ISSN
0022-9032
e-ISSN
1897-4279
Volume of the periodical
83
Issue of the periodical within the volume
11
Country of publishing house
PL - POLAND
Number of pages
3
Pages from-to
1331-1333
UT code for WoS article
001636256600001