All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Transmission energy dispersive X-ray diffraction as a tool for the laboratory study of fast processes in metals

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26316919%3A_____%2F25%3AN0000038" target="_blank" >RIV/26316919:_____/25:N0000038 - isvavai.cz</a>

  • Alternative codes found

    RIV/68378297:_____/25:00638426 RIV/49777513:23220/25:43976119 RIV/68407700:21670/25:00385678

  • Result on the web

    <a href="https://www.nature.com/articles/s41598-025-16314-9" target="_blank" >https://www.nature.com/articles/s41598-025-16314-9</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1038/s41598-025-16314-9" target="_blank" >10.1038/s41598-025-16314-9</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Transmission energy dispersive X-ray diffraction as a tool for the laboratory study of fast processes in metals

  • Original language description

    In this work, an in-situ study of phase transitions in low-carbon steel is presented. The phase changes were monitored by the transmission energy dispersive X-ray diffraction technique during the heating, annealing and quenching cycle of the sample under standard laboratory conditions. During energy dispersive X-ray diffraction, the sample volume was transmitted with a pencil beam generated by a standard polychromatic X-ray tube without any spectral filtering. Two-dimensional polychromatic diffraction images were acquired by a Timepix 3 pixelated detector. This detector is capable of achieving a throughput of up to 38 Mhits/s in continuous stream mode using USB 3.0 interface. For each detected photon, its position is known with an accuracy of 55 mu m in the detector plane and its energy with a resolution of 4 keV at 60 keV. The recorded polychromatic data is then recomputed to get the equivalent monochromatic XRD pattern that would be produced using a monochromatic X-ray source. Thanks to the 90 kV voltage potential of the X-ray tube, the polychromatic pencil beam was able to pass through a highly attenuating sample made of 1.5 thick steel sheet. In addition, by utilizing the entire X-ray spectrum, the pencil beam has a sufficiently high brilliance to obtain XRD patterns rapidly enough to investigate relatively fast processes with temporal resolution of 10 s. It made to possible to analyze the phase transitions in a polycrystalline sample during its temperature treatment under standard laboratory conditions.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20501 - Materials engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    SCIENTIFIC REPORTS

  • ISSN

    2045-2322

  • e-ISSN

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    16

  • Pages from-to

    nestránkováno

  • UT code for WoS article

    001580990800008

  • EID of the result in the Scopus database

    2-s2.0-105014616888