All
All

What are you looking for?

All
Projects
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Measurement of thermal neutron beam parameters in the LVR-15 research reactor

Result description

Proceedings of the Joint IGORR and IAEA technical meeting, October 13-18, 2013, Daejeon, Korea. The LVR-15 research reactor, situated at the site of the Research Centre Řež near Prague, is equipped with ten horizontal channels. In 2012, into one of thema special filter was mounted and a radiation shielding box was established around the channel in order to take preparations for a future neutron transmission radiography and tomography facility. Basic beam parameters comprise neutron fluence rate and spectrum, and spatial thermal neutron distribution (beam divergence). These parameters were measured with activation detectors and a silicon detector with a 6Li converter. In addition, the gamma dose rate at the channel outlet was measured using TLD dosimeters. The measured thermal neutron fluence rate was determined at the value of about 2x108 cm-2.s-1 and beam homogeneity was proclaimed acceptable at a diameter of 100 mm for the future neutron radiography facility. The results were discus

Keywords

research reactorsLVR-15 reactorneutron beamsneutron fluence measurement

The result's identifiers

Alternative languages

  • Result language

    angličtina

  • Original language name

    Measurement of thermal neutron beam parameters in the LVR-15 research reactor

  • Original language description

    Proceedings of the Joint IGORR and IAEA technical meeting, October 13-18, 2013, Daejeon, Korea. The LVR-15 research reactor, situated at the site of the Research Centre Řež near Prague, is equipped with ten horizontal channels. In 2012, into one of thema special filter was mounted and a radiation shielding box was established around the channel in order to take preparations for a future neutron transmission radiography and tomography facility. Basic beam parameters comprise neutron fluence rate and spectrum, and spatial thermal neutron distribution (beam divergence). These parameters were measured with activation detectors and a silicon detector with a 6Li converter. In addition, the gamma dose rate at the channel outlet was measured using TLD dosimeters. The measured thermal neutron fluence rate was determined at the value of about 2x108 cm-2.s-1 and beam homogeneity was proclaimed acceptable at a diameter of 100 mm for the future neutron radiography facility. The results were discus

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    JF - Nuclear energy

  • OECD FORD branch

Result continuities

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů