Ratio of spectral averaged cross sections measured in 252-Cf(sf) and 235-U(nth,f) neutron fields
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F20%3AN0000180" target="_blank" >RIV/26722445:_____/20:N0000180 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1051/epjconf/202023919004" target="_blank" >http://dx.doi.org/10.1051/epjconf/202023919004</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/202023919004" target="_blank" >10.1051/epjconf/202023919004</a>
Alternative languages
Result language
angličtina
Original language name
Ratio of spectral averaged cross sections measured in 252-Cf(sf) and 235-U(nth,f) neutron fields
Original language description
The results of systematic evaluations of spectrum averaged cross section (SACS) measurements in the fission neutron fields of 252-Cf and 235-U are presented. The data form a complete database of high-threshold experimental SACS measured in the same installation under the same conditions and using the same high purity germanium gamma spectrometer. This is crucial to reduce the uncertainty of the ratio and the data scattering and therefore, to minimize discrepancies compared to cross section measured under different conditions in different laboratories. This new dataset complements and extends earlier experimental evaluations.The total emission of the 252-Cf neutron source during the experiments varied from 9.5E8 to 4.5E8 neutrons per second. The emission was derived in accordance to the data in the Certificate of Calibration involving absolute flux measurements in a manganese sulphate bath. Concerning 235-U fission neutron field, the irradiations were carried out in a specifically designed core assembled in the zero power light water LR-0 reactor. This special core has well described neutron field. After the irradiation, the low volume irradiated samples to be measured by gamma spectrometry were placed directly on the upper cap of a coaxial high purity germanium (HPGe) detector in a vertical configuration (ORTEC GEM35P4). High volume samples were homogenized and strewn into the Marinelli beaker. HPGe detector is surrounded by the lead shielding box with a thin inner copper cladding and covered with rubber for suppression of background signal and bremsstrahlung. The experimental reaction rates were derived for irradiated samples from the Net Peak Areas (NPA) measured using the semiconductor HPGe detector. The measured reaction rates are used to derive the spectrum-averaged cross sections. Furthermore, measured reaction rates are also compared with MCNP6 calculations using various nuclear data libraries, in particular IRDFF evaluations.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
10303 - Particles and field physics
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
EPJ Web of Conferences 239, 19004 (2020)
ISBN
—
ISSN
2100-014X
e-ISSN
—
Number of pages
4
Pages from-to
1-4
Publisher name
EDP Sciences
Place of publication
—
Event location
Beijing, China
Event date
May 19, 2019
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—