The Impacts of the Sterilization Method and the Electrospinning Conditions of Nanofibrous Biodegradable Layers on Their Degradation and Hemocompatibility Behavior
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F27283933%3A_____%2F24%3AN0000010" target="_blank" >RIV/27283933:_____/24:N0000010 - isvavai.cz</a>
Alternative codes found
RIV/46747885:24530/24:00012304 RIV/46747885:24410/24:00012304 RIV/46747885:24510/24:00012304 RIV/00216208:11140/24:10479766
Result on the web
<a href="https://www.mdpi.com/2073-4360/16/8/1029" target="_blank" >https://www.mdpi.com/2073-4360/16/8/1029</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/polym16081029" target="_blank" >10.3390/polym16081029</a>
Alternative languages
Result language
angličtina
Original language name
The Impacts of the Sterilization Method and the Electrospinning Conditions of Nanofibrous Biodegradable Layers on Their Degradation and Hemocompatibility Behavior
Original language description
The use of electrospun polymeric biodegradable materials for medical applications is becoming increasingly widespread. One of the most important parameters regarding the functionality of nanofiber scaffolds during implantation and the subsequent regeneration of damaged tissues concerns their stability and degradation behavior, both of which are influenced by a wide range of factors (the properties of the polymer and the polymer solution, the technological processing approach, the sterilization method, etc.). This study monitored the degradation of nanofibrous materials fabricated from degradable polyesters as a result of the sterilization method applied (ethylene oxide and gamma irradiation) and the solvent system used to prepare the spun polymer solution. Aliphatic polyesters PCL and PLCL were chosen for this study and selected with respect to the applicability and handling in the surgical setting of these nanofibrous materials for vascular bandaging. The results revealed that the choice of solvent system exerts a significant impact on degradation during sterilization, especially at higher gamma irradiation values. The subsequent enzyme-catalyzed degradation of the materials following sterilization indicated that the choice of the sterilization method influenced the degradation behavior of the materials. Whereas wave-like degradation was evident concerning ethylene oxide sterilization, no such behavior was observed following gamma-irradiation sterilization. With concern for some of the tested materials, the results also indicated the potential for influencing the development of degradation within the bulk versus degradation from the surface of the material. Both the sterilization method and the choice of the spinning solvent system were found to impact degradation, which was observed to be most accelerated in the case of PLCL (L-lactide-co-caprolactone copolymer) electrospun from organic acids and subsequently sterilized using gamma irradiation. Since we planned to use these materials in cardiovascular applications, it was decided that their hemocompatibility would also be tested. The results of these tests revealed that changes in the structures of the materials initiated by sterilization may exert thrombogenic and anticoagulant impacts. Moreover, the microscopic analysis suggested that the solvent system used in the preparation of the materials potentially affects the behavior of erythrocytes; however, no indication of the occurrence of hemolysis was detected.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30404 - Biomaterials (as related to medical implants, devices, sensors)
Result continuities
Project
<a href="/en/project/NU20-02-00368" target="_blank" >NU20-02-00368: Biomechanically defined absorbable materials for cardiovascular surgery</a><br>
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2024
Confidentiality
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Data specific for result type
Name of the periodical
Polymers
ISSN
2073-4360
e-ISSN
2073-4360
Volume of the periodical
16
Issue of the periodical within the volume
8
Country of publishing house
CH - SWITZERLAND
Number of pages
32
Pages from-to
nestrankovano
UT code for WoS article
001220349000001
EID of the result in the Scopus database
2-s2.0-85191369729