Measurement of non-effective electric current in electrodialysis stacks
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F28676092%3A_____%2F17%3AN0000028" target="_blank" >RIV/28676092:_____/17:N0000028 - isvavai.cz</a>
Alternative codes found
RIV/46747885:24220/17:00008818
Result on the web
<a href="http://www.scopus.com/inward/record.uri?eid=2-s2.0-85042365797&doi=10.1149%2f2.1481709jes&partnerID=40&md5=f00fca4710c43bcf59f00590188a0885" target="_blank" >http://www.scopus.com/inward/record.uri?eid=2-s2.0-85042365797&doi=10.1149%2f2.1481709jes&partnerID=40&md5=f00fca4710c43bcf59f00590188a0885</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1149/2.1481709jes" target="_blank" >10.1149/2.1481709jes</a>
Alternative languages
Result language
angličtina
Original language name
Measurement of non-effective electric current in electrodialysis stacks
Original language description
The driving force of electrodialysis is applied voltage and electric current. In the event that the module is composed of a number of mutually hydraulically connected subunits (membrane pairs), electric current passes through a part outside the active part along peripherals providing the supply of raw materials. This work focuses on the measurement of these currents that are lost inefficiently. The influence of module geometry on electrodialysis, conductivity of working solutions and applied voltage were studied. The influence of the presence of an ion-conductive membrane in the sealing area on the performance of a membrane stack has been proven. A relation between the conductivity of a membrane and the conductivity of electrolytes to the amount of leakage currents has been found. On the contrary, voltage applied does not primarily influence the distribution of leakage currents but it affects the degree of desalination and the conductivity of solutions in collecting and feeding channels. In the pilot and operating modules with 25 and 50 membrane pairs that were used, the calculated leakage current reaches 0.2–1.2% of the total current load depending on the design and operating conditions.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20401 - Chemical engineering (plants, products)
Result continuities
Project
<a href="/en/project/FR-TI4%2F398" target="_blank" >FR-TI4/398: Research, development and aplication of new generation electromembrane modules</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Data specific for result type
Name of the periodical
Journal of The Electrochemical Society
ISSN
0013-4651
e-ISSN
—
Volume of the periodical
2017/ 9
Issue of the periodical within the volume
Volume 164
Country of publishing house
US - UNITED STATES
Number of pages
7
Pages from-to
276-282
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85042365797