Smartphone-Based Data Acquisition Method for Modelling 3D Printed Arm Casts

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13420%2F23%3A43898097" target="_blank" >RIV/44555601:13420/23:43898097 - isvavai.cz</a>

  • Result on the web

    <a href="https://journalmt.com/artkey/mft-202302-0006_smartphone-based-data-acquisition-method-for-modelling-3d-printed-arm-casts.php" target="_blank" >https://journalmt.com/artkey/mft-202302-0006_smartphone-based-data-acquisition-method-for-modelling-3d-printed-arm-casts.php</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.21062/mft.2023.019" target="_blank" >10.21062/mft.2023.019</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Smartphone-Based Data Acquisition Method for Modelling 3D Printed Arm Casts

  • Original language description

    In recent years, 3D printed arm casts can replace traditional arm casts to treat bones fractures. 3D printed arm cast modelling often uses professional 3D scanning systems to capture 3D data of the arm. These systems are very expensive and may not be available in many hospitals. In order to overcome this disadvantage, inexpensive methods should be developed. This paper introduces a new data collection method based on smartphones. The photos of an arm were taken with a smartphone camera using some special techniques that could facilitate the process of image processing and 3D modelling in Agisoft Metashape and CATIA. To validate the proposed method, the photogrammetric model was compared with the scanned model (obtained by a low cost scanner) in GOM Inspect. Besides, a fit check of real 3D printed arm casts attached on the volunteer&apos;s forearm was also performed. The test results indicate that the photogrammetric model could be used as raw data for 3D arm modelling.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20301 - Mechanical engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Manufacturing Technology

  • ISSN

    1213-2489

  • e-ISSN

    2787-9402

  • Volume of the periodical

    23

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    8

  • Pages from-to

    260-267

  • UT code for WoS article

    000975659300015

  • EID of the result in the Scopus database

    2-s2.0-85159016347