All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Electrical condition monitoring techniques for low-voltage cables used in nuclear power plants

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46356088%3A_____%2F13%3A%230001448" target="_blank" >RIV/46356088:_____/13:#0001448 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1109/EIC.2013.6554299" target="_blank" >http://dx.doi.org/10.1109/EIC.2013.6554299</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EIC.2013.6554299" target="_blank" >10.1109/EIC.2013.6554299</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Electrical condition monitoring techniques for low-voltage cables used in nuclear power plants

  • Original language description

    In this paper, dielectric spectroscopy is adapted to investigate the dielectric response, in the frequency range 10-2-106Hz, of a low-voltage cable for nuclear power plants. Cable samples were aged under accelerated stress conditions up to an equivalentaging time of 60 years. The aging procedure consisted of two phases: thermal aging by means of high temperature followed by gamma-irradiation at room temperature. Dielectric spectroscopy has been adapted to measure the dissipation factor Tan(?) of innerinsulation and outer sheath. A significant reduction of Tan(?) can be observed in the frequency range 101-104Hz, indicating that accelerated aging process mainly affects the dipolar polarization. Furthermore, the shape of the dielectric response presentsa global minimum which shifts to lower frequency as the aging time increases. Experimental results show that the frequency in correspondence of this minimum value, as well as Tan(?) at the reference frequency of 100 Hz, can be used as ag

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JF - Nuclear energy

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    R - Projekt Ramcoveho programu EK

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2013 IEEE Electrical Insulation Conference, EIC 2013

  • ISBN

    978-1-4673-4739-6

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    504-508

  • Publisher name

    IEEE

  • Place of publication

  • Event location

    Ottawa, Canada

  • Event date

    Jan 1, 2013

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000326735500102