MEASUREMENT OF THE IMPUSLIVE FORCE GENERATED BY COLAPSING BUBBLE CLOSE TO A SOLID BOUNDARY

Result description

The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power leddiode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.

Keywords

colapsing bubble

The result's identifiers

Alternative languages

  • Result language

    angličtina

  • Original language name

    MEASUREMENT OF THE IMPUSLIVE FORCE GENERATED BY COLAPSING BUBBLE CLOSE TO A SOLID BOUNDARY

  • Original language description

    The article presents experimental results of the acoustical and optical study of cavitation bubble collapse close to a solid boundary in water. The bubble was generated by discharge of low-voltage capacitor into a couple of wires closing a simple circuit. Different distances from the solid wall and different maximum bubble radii were studied. The bubble radius was studied using time-resolved photography and by PVDF film sensor glued on the solid boundary. The illumination was provided by high-power leddiode. Synchronization of the system was provided by pulse generator connected to an oscilloscope. The impact power of the bubble to the wall was estimated from the time-resolved photography of the bubble and from the PVDF film sensor signal. The PVDF film sensor calibration was performed by a pendulum test to estimate the impact force.

  • Czech name

  • Czech description

Classification

  • Type

    Jx - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BK - Liquid mechanics

  • OECD FORD branch

Result continuities

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    EPJ Web of Conferences

  • ISSN

    2100-014X

  • e-ISSN

  • Volume of the periodical

  • Issue of the periodical within the volume

    25

  • Country of publishing house

    FR - FRANCE

  • Number of pages

    6

  • Pages from-to

    "01058-p.1"-"01058-p.6"

  • UT code for WoS article

  • EID of the result in the Scopus database

Basic information

Result type

Jx - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

Jx

CEP

BK - Liquid mechanics

Year of implementation

2012