All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Numerical Evaluation of Scar After Breast Reconstruction with Abdominal Advacement Flap

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F16%3A00001068" target="_blank" >RIV/46747885:24210/16:00001068 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Numerical Evaluation of Scar After Breast Reconstruction with Abdominal Advacement Flap

  • Original language description

    The treatment of breast cancer has been developed a lot last decade, nevertheless it's still is a considerable social and economical matter in all countries of the world. The choice of the surgery depends on a patient´s protocol and the surgeon´s preferences.The aim of this study is to evaluate the scar loading after breast reconstruction.Methods The mathematical modeling of the sutured skin flap used for breast implant's placing was divided into following two steps. First a material model of the selected silicone implant was identified. Second the mathematical model of the breast and implant was performed. Results The maximal geometrical deviation for anatomical and elliptical implant is on the lower surface of the breast and upper surface of the breast, while in the region of lateral geometry and the area around nipple the agreement is very high. The maximal tension is located in two median stitches. The maximal force reaches 0.025 N. The equivalent Cauchy stress is located around the nipple reaches the value 380 kPa. Conclusion From our results can be seen, that the anatomical and elliptical breast implant didn´t resulted into the same scar loading. The maximal value difference reaches 13.4 % between stress values for these two breast implants. So that the round implant resulted in higher loaded scar than the anatomical one.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JR - Other machinery industry

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Acta Chirurgiae Plasticae

  • ISSN

    0001-5423

  • e-ISSN

  • Volume of the periodical

    58

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    6

  • Pages from-to

    12-17

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-84996539929