Influence of carbon fiber fraction on plaster composities ability to electromagnetic shielding
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F16%3A00003701" target="_blank" >RIV/46747885:24210/16:00003701 - isvavai.cz</a>
Alternative codes found
RIV/46747885:24410/16:00003701
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Influence of carbon fiber fraction on plaster composities ability to electromagnetic shielding
Original language description
This paper studies size of electromagnetic shielding in plaster composites, using different volume fractions of carbon fiber. The base matrix of the the composite was a special thermal-insulation plaster ThermoUM Xtra. Into the plaster, as reinforcing and simultaneously shielding element carbon microfibers with a length of 7 mm were added. Test samples were made at three different volume fractions and also on a base plaster for possibilities of their comparison. The measurement results show that the electromagnetic shielding grows with increasing fiber content in the plaster composite in the tested ratio almost linearly.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
JI - Composite materials
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2016
Confidentiality