Control Unit of Pneumatic System with pressure recuperation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F24%3A00012671" target="_blank" >RIV/46747885:24210/24:00012671 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Control Unit of Pneumatic System with pressure recuperation
Original language description
It is a control unit of pneumatic system. It allows the recuperation of the pressure. This working sample is a controller that is built on the Arduino micro development board. The unit provides pressure control in two pneumatic elements simultaneously. It is applicable for a variable stiffness seat cushion with two zones or for a variable stiffness orthopaedic mattress with two zones. When adjusting the pressure in each zone, it reduces the amount of pressurised air required by not venting the air out to the atmosphere when the pressure is reduced, but using it to increase the pressure in the adjacent zone if necessary.
Czech name
—
Czech description
—
Classification
Type
G<sub>funk</sub> - Functional sample
CEP classification
—
OECD FORD branch
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Internal product ID
KSA-2024-16
Numerical identification
—
Technical parameters
The core of the controller is an Arduino Micro, which is equipped with terminals for connecting controls, sensors and pneumatic valves. The pressures in both zones are set using buttons or potentiometers. The buttons are connected to digital inputs D5-D8. The potentiometers are connected to analog inputs A0 and A1. The pressure sensors are analog 0-5V in the range -100-100kPa and they are connected to analog inputs A2 and A3. The valves are two-state connected via TLP250 optical isolators. The unit can control five valves, two to fill, two to drain and one is between the zones. Kontaktní osoba Radek Votrubec (radek.votrubec@tul.cz).
Economical parameters
jednotka je součástí většího celku s komerčním potenciálem.
Application category by cost
—
Owner IČO
46747885
Owner name
Technická univerzita v Liberci
Owner country
CZ - CZECH REPUBLIC
Usage type
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Licence fee requirement
N - Poskytovatel licence na výsledek nepožaduje licenční poplatek