The Change of Cardiostimulation Device Programming Due to Detection of Electromagnetic Interference

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F20%3A00008122" target="_blank" >RIV/46747885:24220/20:00008122 - isvavai.cz</a>

  • Result on the web

    <a href="https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/6879" target="_blank" >https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/6879</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.14311/CTJ.2020.2.04" target="_blank" >10.14311/CTJ.2020.2.04</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Change of Cardiostimulation Device Programming Due to Detection of Electromagnetic Interference

  • Original language description

    The study deals with the interdisciplinary topic of the electromagnetic compatibility of the cardiac implantable electronic devices that are used in patients with a defect of heart conduction system. We are focusing on the detection of disturbing signals on electrodes of cardiostimulation device and its interpretation. The detection of electromagnetic interference (EMI) is related to electrode choice, device placement, its configuration and programming. The aim of the study is the analysis of the pacemaker response in the presence of an external source of the disturbance fields. We point to possible risks of its interaction and discuss mechanisms that can influence the pacemaker sensitivity to EMI. Due to improper signal detection, the device programming changes can occur. We present an experiment of the exposure of the cardiostimulation system to a low-frequency harmonic interference signals and finally we analyse similar clinical episode and discuss proper functioning of the pacemaker.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Lékař a technika - Clinician and Technology

  • ISSN

    0301-5491

  • e-ISSN

  • Volume of the periodical

    50

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    4

  • Pages from-to

    65-68

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85099965954