Silver-plated stretchable elastomeric electrodes for electrotherapy applications
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F24%3A00013325" target="_blank" >RIV/46747885:24410/24:00013325 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1177/15280837241287561" target="_blank" >https://doi.org/10.1177/15280837241287561</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/15280837241287561" target="_blank" >10.1177/15280837241287561</a>
Alternative languages
Result language
angličtina
Original language name
Silver-plated stretchable elastomeric electrodes for electrotherapy applications
Original language description
The present study aimed to develop wearable, electrically conductive hygienic electrodes and their use for Transcutaneous Electrical Nerve Stimulation (TENS) application. The development of electrodes was done in two stages. Firstly, the dispersion of conductive activated carbon particles was done into flexible elastomer followed by its silver electroplating. The Orthogonal Array Testing (OATS) technique was used to optimize the silver-plating recipe. The Fourier transform infrared spectroscopy (FTIR) analysis confirmed the impact of activated carbon by increase in intensity of stretching bands. To improve electrode properties in response to various human body movements, resistivity changes due to stretching and repeated extension were tested on conductive elastomers. Increasing the extension degree allowed a very minute change in electrical resistivity. Therefore, the resistivity can be considered almost constant within the 0-60 % stretch range. While, a notable increase in electrical resistivity was observed after 70 % of stretch. However, the resistivity of elastomers remained stable even after repetitive extension (for over 100 cycles). Conversely, no significant change in resistivity was observed over time when subjected to a constant current. Furthermore, to minimize the effect of skin electrode resistivity during electrotherapy, the range of different pressure was applied over the surface of electrodes. Minimum value of resistivity about 1 Omega.mm was obtained at 6 N/cm2 of applied pressure. Additionally, hygienic properties, such as antiviral, antibacterial and antifungal were examined using different pathogens to assess the impact of the deposited silver particles. In the end, the durability of electrodes against washing and rubbing was confirmed. The potential applications of prepared electrodes are in the field of electrostimulation and electrotherapy etc.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20503 - Textiles; including synthetic dyes, colours, fibres (nanoscale materials to be 2.10; biomaterials to be 2.9)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JOURNAL OF INDUSTRIAL TEXTILES
ISSN
1528-0837
e-ISSN
—
Volume of the periodical
54
Issue of the periodical within the volume
SEP
Country of publishing house
US - UNITED STATES
Number of pages
29
Pages from-to
—
UT code for WoS article
001322708400001
EID of the result in the Scopus database
2-s2.0-85213546709