Electronic System for Measuring and Optimization of Pacemaker Pulses
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F13%3A43918812" target="_blank" >RIV/49777513:23220/13:43918812 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/13:10139675 RIV/00669806:_____/13:10139675
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Electronic System for Measuring and Optimization of Pacemaker Pulses
Original language description
A pacemaker is a small electronic device implanted under the skin near the collarbone. Pacemakers monitor the heart?s electrical activity. If the heart is beating too slowly or pausing too long between beats, the pacemaker will provide electrical impulses that stimulate the heart to beat. The pacemaker itself consists of a small box (the pulse generator) and one to three leads that are placed in the heart. This paper is devoted to electronic evaluating system which enables to find (in coordination withphysician) an optimal pacemaker electrical impulses, e.g. pulse width, amplitude, delay and lead (or leads) position in heart to reducing the delivered energy. Inputs of electronic evaluating system are taken from ECG (electro cardio graph) and Finapres(system for continuous measuring of blood pressure). Results will be helpful for prolonging battery longevity and reducing the stimuli pain on patients with implantable medical devices. There are present results of different approach base
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
FS - Medical facilities, apparatus and equipment
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regional Innovation Centre for Electrical Engineering (RICE)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
RECENT ADVANCES in TELECOMMUNICATIONS and CIRCUIT DESIGN
ISBN
978-960-474-310-0
ISSN
1790-5117
e-ISSN
—
Number of pages
7
Pages from-to
42-48
Publisher name
WSEAS Press
Place of publication
Athens
Event location
Rhodos
Event date
Jul 16, 2013
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—