Simulation of Voltage and Temperature Distributions in End Part of Windings of Synchronous Generator
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F14%3A43923324" target="_blank" >RIV/49777513:23220/14:43923324 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Simulation of Voltage and Temperature Distributions in End Part of Windings of Synchronous Generator
Original language description
The nonlinear electric field in stator coils of synchronous generators and its increase causes surface discharges. The ECP (end winding corona protection) is usually applied to suppress their undesirable effects. The ECP is exposed to several types of mechanical, electrical and thermal stresses in the process of testing the coils and during the operation of the machine. This paper focuses on the voltage and temperature distributions along this protection. Distributions of voltage and temperature were measured, simulated and finally compared. The aim of the work is to verify the suggested mathematical model which would help to save time and costs associated with the ECP design.