Changes of insulation resistance of fire resistant cable under fire conditions

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43926335" target="_blank" >RIV/49777513:23220/15:43926335 - isvavai.cz</a>

  • Result on the web

    <a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7352028" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7352028</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/CEIDP.2015.7352028" target="_blank" >10.1109/CEIDP.2015.7352028</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Changes of insulation resistance of fire resistant cable under fire conditions

  • Original language description

    Low-fire-hazard cable (LFHC) intended for low voltage applications with a fire barrier made from mica tape was tested under conditions similar to those of the fire test specified in IEC 60331-21. In addition to the other standard requirements, the measurement setup was modified to enable insulation resistance measurement throughout the entire fire test. In this manner, cable insulation as a whole can be tested under fire conditions. Results from insulation resistance measurement are supported by thermogravimetric analysis and by the data obtained from two thermocouples placed near the cable sheath and inside the cable core during the test. As results show, insulation resistance is markedly affected by the melting of the organic components of insulation, by decomposition of the flame retardant and by ignition of the core insulation along the first period of the test (10 minutes). The stable value of the insulation resistance from 10th to 90th minutes of testing, together with the insula

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regional Innovation Centre for Electrical Engineering (RICE)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2015)

  • ISBN

    978-1-4673-7497-2

  • ISSN

    0084-9162

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    278-281

  • Publisher name

    IEEE

  • Place of publication

    Piscataway

  • Event location

    Michigan, USA

  • Event date

    Oct 18, 2015

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article