All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

A synchronization and data acquisition system for silicon detectors

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F18%3A43953072" target="_blank" >RIV/49777513:23220/18:43953072 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21670/18:00328384

  • Result on the web

    <a href="http://iopscience.iop.org/article/10.1088/1748-0221/13/11/C11019/meta" target="_blank" >http://iopscience.iop.org/article/10.1088/1748-0221/13/11/C11019/meta</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/13/11/C11019" target="_blank" >10.1088/1748-0221/13/11/C11019</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A synchronization and data acquisition system for silicon detectors

  • Original language description

    A dedicated synchronization bus has been developed and integrated into the FITPix COMBO device. It can be used as Timepix read-out (involving back-side-pulse acquisition) or as a simple spectrometer device—Spectrig (when an external single pad sensor is connected, e.g. Δ E detector). The synchronization bus permits the implementation of a system of up to 32 distinct devices running in clock locked mode while the absolute value of the timestamp is distributed to all devices in the system. Any combination of Timepix or spectrometer devices (up to 32) can be connected-up to create a final measurement set-up. The synchronization bus has also been designed to control a trigger signal and busy signal to allow an effective filtration of unpaired events when coincidence measurement is performed. The system has been tested with a Δ E− E telescope consisting of a thin detector and Timepix. The thin detector has been used for Δ E and the Timepix detector for E measurements. The Δ E detector has an area of 10×10 mm2 and a thickness of 12 μm with non-uniformity of 8%. The area and thickness of Timepix are 14×14 mm2 and 300 μm, respectively. The detection system can provide simultaneous information about position, energy, time and type of registered particles with high synchronization accuracy. Test measurements have been carried out with an alpha particle source (Ra-226) in a vacuum and the results of these measurements are presented in this paper.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20305 - Nuclear related engineering; (nuclear physics to be 1.3);

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    November

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    9

  • Pages from-to

    0-8

  • UT code for WoS article

    000451408400001

  • EID of the result in the Scopus database

    2-s2.0-85057599291