Hodoscope with Timepix detectors for PilsenCube2 cubesat

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F20%3A43959193" target="_blank" >RIV/49777513:23220/20:43959193 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21670/20:00344673

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0168900220308597" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0168900220308597</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nima.2020.164462" target="_blank" >10.1016/j.nima.2020.164462</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Hodoscope with Timepix detectors for PilsenCube2 cubesat

  • Original language description

    The contribution describes the design of Timepix-based hodoscope for cubesat applications, such as Pilsen-Cube2, developed by the University of West Bohemia. The hodoscope is composed of two Timepix detectors with silicon thickness of 300 μm, placed in back-to-back arrangement and rotated relative to each other by 90◦, forming a telescope set-up. A copper separator is placed between two detectors to distinguish electrons and protons. The payload hardware and firmware are designed to support single detector operation as well as dual detector operation mode, in which particle coincidence detection is possible. The hodoscope electronic has been designed with respect to harsh radiation environment present in LEO (Low Earth Orbit). The device involves independent radiation hardened power supplies, including bias high voltage supply (up to 250 V) and auxiliary threshold reference DAC for each Timepix detector. Considering highly limited achievable data throughput between the CubeSat and the ground control station, advanced on-board data processing has been developed to reduce the size of transmitted data. The on-board data processing is provided by the radiation hardened SoC (System on Chip) Smartfusion2.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10303 - Particles and field physics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    NUCLEAR INSTRUMENTS &amp; METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT

  • ISSN

    0168-9002

  • e-ISSN

  • Volume of the periodical

    980

  • Issue of the periodical within the volume

    November 2020

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    8

  • Pages from-to

    1-8

  • UT code for WoS article

    000576959300012

  • EID of the result in the Scopus database