Development and testing of compact electronic modules for detectors based on SiPM array
Original language description
Background: Compact electronic modules are essential for modern detector systems utilizing Silicon Photomultiplier (SiPM) arrays due to their small size, low power consumption, and high precision. To address the growing demand for portable and efficient detection systems, the development of modules tailored for such applications has become a critical focus. This study introduces compact electronic modules designed for detectors based on MAPD (Microcell Avalanche Photodiode) arrays, aiming to improve reliability and versatility for industrial, medical, and scientific applications. Methods: The developed modules include two primary components: DC-DC Voltage Converter: Based on the MAX1932ETC chip. Converts a 5 V input to a stable output voltage adjustable between 30 and 90 V. Supports a maximum current of 2.5 mA, ensuring reliable operation for SiPM arrays. Signal Amplification Unit: Utilizes the LTC6268 chip. Processes input signals ranging from 10 to 75 mV. Offers a gain factor of 45, characterized by low noise and high precision. The modules were integrated with a scintillation detector comprising a MAPD-3NM-II photodiode array and an LFs scintillator. Performance testing was conducted using a Cs-137 gamma source. Results: The energy resolution of the detector system was evaluated using the 662 keV gamma line from the Cs-137 source. The modules achieved an energy resolution of 10 ± 0.5%, demonstrating high reliability and efficiency. This performance confirms the modules’ capability to maintain stable operation and precise signal processing under real-world conditions. Conclusions: The developed compact electronic modules provide a cost-effective and efficient solution for detectors utilizing SiPM arrays. Their stable voltage conversion, low-noise signal amplification, and high energy resolution make them suitable for a wide range of applications in industrial, medical, and scientific fields. Future work may focus on optimizing the modules for broader voltage ranges and compatibility with different scintillator materials to expand their applicability.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Open Research Europe
ISSN
2732-5121
e-ISSN
2732-5121
Volume of the periodical
5
Issue of the periodical within the volume
October 2025
Country of publishing house
GB - UNITED KINGDOM
Number of pages
11
Pages from-to
1-11
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-105018216815