All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fully contactless system for crayfish heartbeat monitoring: Undisturbed crayfish as bio-indicator

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F18%3A43895995" target="_blank" >RIV/60076658:12520/18:43895995 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0925400517313746?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0925400517313746?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.snb.2017.07.160" target="_blank" >10.1016/j.snb.2017.07.160</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fully contactless system for crayfish heartbeat monitoring: Undisturbed crayfish as bio-indicator

  • Original language description

    The crayfish is widely accepted as very sensitive and fast bio-indicator of changes in water quality. Studies based on heart beat analysis demonstrated the potential of using crayfish as a detector of pollutants consequently several computer-aided systems were developed to use this mechanism. The main complication with applying such a system is the necessity of using metal wires or optical fibres to transmit the signal from sensor which is placed on back of the crayfish to the processing hardware; these attachments restrict system design to one crayfish in one aquarium. We introduced an original system for crayfish heart beat monitoring based on completely non-invasive/contactless hardware. The system can determine crayfish heart beat frequency using only the combination of near infra-red (NIR) illuminator and sensitive camera. The heart rate is the only parameter needed in most of the studies using crayfish as a bio-indicator. We developed the system which needs no attachment, so more crayfish in one aquarium can be monitored simultaneously and it provides accurate information on heart rate and crayfish need no adaptation to the system. It can be used as equivalent to existing systems to simplify the crayfish studies. (C) 2017 Published by Elsevier B.V.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10610 - Biophysics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Recent Sensors and Actuators B: Chemical

  • ISSN

    0925-4005

  • e-ISSN

  • Volume of the periodical

    255

  • Issue of the periodical within the volume

    2/2018

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    6

  • Pages from-to

    29-34

  • UT code for WoS article

    000414151800004

  • EID of the result in the Scopus database

    2-s2.0-85029421879