Performance comparison of three passive samplers for monitoring of polar organic contaminants in treated municipal wastewater
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F24%3A43908048" target="_blank" >RIV/60076658:12520/24:43908048 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14310/24:00135706
Result on the web
<a href="https://doi.org/10.1016/j.scitotenv.2023.168153" target="_blank" >https://doi.org/10.1016/j.scitotenv.2023.168153</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.scitotenv.2023.168153" target="_blank" >10.1016/j.scitotenv.2023.168153</a>
Alternative languages
Result language
angličtina
Original language name
Performance comparison of three passive samplers for monitoring of polar organic contaminants in treated municipal wastewater
Original language description
Over the past decades, several types of passive samplers have been developed and used to monitor polar organic compounds in aquatic environments. These samplers use different sorbents and barriers to control the uptake into the sampler, but their performance comparison is usually not well investigated. This study aimed to directly compare the performance of three samplers, i.e., the Polar Organic Chemical Integrative Sampler (POCIS), the Hydrogel-based Passive Sampler (HPS, an upscaled version of o-DGT), and the Speedisk, on a diverse suite of pharmaceuticals, per- and polyfluoroalkylated substances (PFAS), and pesticides and their metabolites. The samplers were deployed side-by-side in the treated effluent of a municipal wastewater treatment plant for different exposure times. All samplers accumulated a comparable number of compounds, and integrative uptake was observed for most compounds detected up to 28 days for POCIS, up to 14 days for HPS, and up to 42 days for Speedisk. In the integrative uptake phase, consistent surface-specific uptake was observed with a significant correlation between samplers (r >= 0.76) despite differences in sampler construction, diffusion barrier, and sorbent material used. The low sampling rates compared to the literature and the low estimated overall mass transfer coefficient suggests that the water boundary layer was the main barrier controlling the uptake for all samplers. Although all devices provided comparable performance, Speedisk overcomes POCIS and HPS in several criteria, including time-integrative sampling over a long period and physical durability.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10511 - Environmental sciences (social aspects to be 5.7)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Science of the Total Environment
ISSN
0048-9697
e-ISSN
1879-1026
Volume of the periodical
908
Issue of the periodical within the volume
neuvedeno
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
12
Pages from-to
—
UT code for WoS article
001109901500001
EID of the result in the Scopus database
2-s2.0-85175802400