Field and laboratory ad hoc calibrations of virrib and thetaprobe dielectric sensors for soil moisture measurements
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60109807%3A_____%2F08%3A%230000100" target="_blank" >RIV/60109807:_____/08:#0000100 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Field and laboratory ad hoc calibrations of virrib and thetaprobe dielectric sensors for soil moisture measurements
Original language description
Jednobodová polní kalibrace byla dělána každé jaro v dodě instalace během tří (pokud jde o čibla Virrib) a dvou (pokud jde o čidla ThetaProbe) po sobě jdoucích let paralelním odečítáním čidel a odběrem půdních vzorků. Dodatečné ověření bylo děláno v laboratoři odečítáním jednotlivých čidel vsunutých do předem připravených hlinito-písčitých směsí o různé vlhkosti. Výsledky nasvědčují, že průměrný sklon sekundární kalibrační křivky Virrib (definovaný jako graf závislosti y = odečet čidla vyjádřený jako objemová vlhkost proti x = vlhkosti určené gravimetricky) je blízký jedné, ale posuny jsou dosti velké a mění se od čidla k čidlu. Sekundární kalibrační křivka čidel ThetaProbe z pole, na rozdíl od laboratorní kalibrační křivky, se jeví kvůli neexistenci velmi nízkých vlhkostí na poli přibližně lineární.
Czech name
Polní a laboratorní ad hoc kalibrace dielektrických čidel virrib a thetaprobe k měření vlhkosti půdy
Czech description
One-point field calibration was made each spring at the time of sensor installation over three (for Virribs) or two (for ThetaProbes) consecutive years by taking sensor readings and soil samples in parallel. A supplementary check was then made in the laboratory by taking readings of individual sensors, inserted into pre-made loamy-sand mixtures with various moisture contents. The results suggest that the average slope of the secondary Virrib calibration curve is near to unity, but the offsets are quitelarge and vary from probe to probe. The field secondary calibration curve of ThetaProbes appears to be roughly linear, in contrast to the laboratory calibration curve, because of absence of very low moisture contents in the field.
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
GD - Fertilization, irrigation, soil treatment
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Soil and water research
ISSN
1801-5395
e-ISSN
—
Volume of the periodical
4
Issue of the periodical within the volume
3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
16
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—