The Capacitive High Voltage Probes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F10%3A00421477" target="_blank" >RIV/60162694:G43__/10:00421477 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
The Capacitive High Voltage Probes
Original language description
This article deals with the design of high voltage capacitive probes for Blumlein pulsed forming line diagnostic. The pulsed forming line feeds a microwave generator working with the virtual cathode (vircator). Because of this type of generator belongs to High Power Microwave (HPM) generator class it is necessary to use special methods of high pulsed voltage measurement when the peak voltage could be about hundreds of kilovolts. This article describes a practical realization of the spherical capacitiveprobe for pulse forming line input voltage measurement and the cylindrical capacitive probe for pulse forming line output voltage measurement.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
KA - Militarism
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
2010 International Conference on Applied Electronics
ISBN
978-80-7043-865-7
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
—
Publisher name
University of West Bohemia
Place of publication
Plzeň
Event location
Plzeň
Event date
Sep 8, 2010
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
—