Precise experimental determination of electrical equivalent circuit parameters for ultrasonic piezoelectric ceramic transducers from their measured characteristics
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F21%3A00556664" target="_blank" >RIV/60162694:G43__/21:00556664 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0041624X20302705" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0041624X20302705</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ultras.2020.106341" target="_blank" >10.1016/j.ultras.2020.106341</a>
Alternative languages
Result language
angličtina
Original language name
Precise experimental determination of electrical equivalent circuit parameters for ultrasonic piezoelectric ceramic transducers from their measured characteristics
Original language description
The letter is devoted to a method for determining electric equivalent circuit parameters of piezoelectric ceramic transducers from their resonance characteristics. These parameters represent equivalents of mechanical damping, effective weight of the oscillating element, compliance of the mechanical element and static capacitance associated with the transducer material. This method is considered cost efficient, focuses on transducers commonly available on the market and is presented on a specific transducer - transmitter. The acquired parameters are important for performing subsequent simulations and defining their suitability for a particular application. However, these parameters are not included in the usual technical documentation of the commercially available piezoelectric ceramic transducers. The key part of this letter is an iterative process of finding the parameters. Before starting the iteration process, it is very important to set default values of these parameters. Then, a linearized system of equations, based on expressing a real part of the impedance, is used to determine these parameters. The advantage of this method is its simplicity to measure only the two above-mentioned characteristics, from which the required parameters can be then calculated. Thus, there is no need for expensive circuit analyzers, which are able to determine these parameters directly. Although the iterative process includes a large number of steps, and therefore can be relatively time consuming, it can be performed on a commercially available computer technology.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10307 - Acoustics
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
ULTRASONICS
ISSN
0041-624X
e-ISSN
1874-9968
Volume of the periodical
112
Issue of the periodical within the volume
2021
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
5
Pages from-to
106341
UT code for WoS article
000620644600007
EID of the result in the Scopus database
2-s2.0-85099449872