Axial Loading of Different Single-pin Dowels and Effect on Withdrawal Strength
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41320%2F18%3A77758" target="_blank" >RIV/60460709:41320/18:77758 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
čeština
Original language name
Axial Loading of Different Single-pin Dowels and Effect on Withdrawal Strength
Original language description
Withdrawal strengths of commercially available hardwood dowels were examined in this work. Multi-grooved dowels with a straight surface pattern and with pre-glued polyvinyl acetate (PVAc) were tested. Additionally, standard dowels with different single- and multi-grooved surface patterns were also tested, which were not pre-glued. Standard dowels were bonded with two types of PVAc and one type of polyurethane (PUR) adhesive. The influence of the type of dowel, the surface pattern, the dowel diameter, and the type of adhesive used on the dowel joint strength were investigated. Lower average strengths were observed for single-grooved dowels with a spiral pattern (4,9 MPa), failures generally occurred at the first or second thread of the spiral groove. For the pre-glued dowels, there were differences in the observed strengths, which depended upon how the PVAc adhesive was activated. Lower withdrawal strengths were noted for the pre-glued dowels when they were activated by dipping them in water (3,0 MPa)
Czech name
Axial Loading of Different Single-pin Dowels and Effect on Withdrawal Strength
Czech description
Withdrawal strengths of commercially available hardwood dowels were examined in this work. Multi-grooved dowels with a straight surface pattern and with pre-glued polyvinyl acetate (PVAc) were tested. Additionally, standard dowels with different single- and multi-grooved surface patterns were also tested, which were not pre-glued. Standard dowels were bonded with two types of PVAc and one type of polyurethane (PUR) adhesive. The influence of the type of dowel, the surface pattern, the dowel diameter, and the type of adhesive used on the dowel joint strength were investigated. Lower average strengths were observed for single-grooved dowels with a spiral pattern (4,9 MPa), failures generally occurred at the first or second thread of the spiral groove. For the pre-glued dowels, there were differences in the observed strengths, which depended upon how the PVAc adhesive was activated. Lower withdrawal strengths were noted for the pre-glued dowels when they were activated by dipping them in water (3,0 MPa)
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20502 - Paper and wood
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
BioResources
ISSN
1930-2126
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
14
Pages from-to
5179-5192
UT code for WoS article
000440506300031
EID of the result in the Scopus database
—