All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Aspects of Selective Laser Melting technology considered in the preparation of trabecular structures for bone tissue substitution

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F20%3A43921449" target="_blank" >RIV/60461373:22310/20:43921449 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21220/20:00349623

  • Result on the web

    <a href="https://www.journalmt.com/artkey/mft-202004-0008_aspects-of-selective-laser-melting-technology-considered-in-the-preparation-of-trabecular-structures-for-bone-t.php" target="_blank" >https://www.journalmt.com/artkey/mft-202004-0008_aspects-of-selective-laser-melting-technology-considered-in-the-preparation-of-trabecular-structures-for-bone-t.php</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.21062/mft.2020.065" target="_blank" >10.21062/mft.2020.065</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Aspects of Selective Laser Melting technology considered in the preparation of trabecular structures for bone tissue substitution

  • Original language description

    In this paper, the possibilities of selective laser melting (SLM), one of metal additive manufacturing technologies, in the preparation of trabecular structures are discussed. Despite great advantages in geometrical freedom, there are specific process-inherent aspects that must be considered before the production of such structures. To verify SLM capabilities, we tested different orientations (horizontal and vertical) and thicknesses (0.2-4.0 mm) of single struts. Significant irregularities in strut thickness and deviations from the designed cross-sectional area were observed. Horizontal struts showed greater geometrical deviations. Based on our observations, a trabecular structure was prepared with all struts inclined 45° from the building platform. Due to the 72% porosity, mechanical properties approached those of the bone, which is beneficial for the application of such structure in orthopaedics for bone tissue substitution.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20501 - Materials engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Manufacturing Technology

  • ISSN

    1213-2489

  • e-ISSN

  • Volume of the periodical

    20

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    9

  • Pages from-to

    507-515

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85098690284