Application of Resistometric Sensors in Investigation of Zinc Corrosion in Simulated Concrete Environments

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F25%3A43931029" target="_blank" >RIV/60461373:22310/25:43931029 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/buildings15040635" target="_blank" >https://doi.org/10.3390/buildings15040635</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/buildings15040635" target="_blank" >10.3390/buildings15040635</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Application of Resistometric Sensors in Investigation of Zinc Corrosion in Simulated Concrete Environments

  • Original language description

    The aim of this paper was to investigate the corrosion behaviour of zinc in simulated concrete solutions using resistometric sensors and to describe the kinetics ofzinc corrosion. The sensors provide corrosion data information in real time; thus, it is a useful technique for observing zinc corrosion behaviour in concrete environments. Thereplacement of carbon steel rebar by galvanized steel in concrete is a discussable topic with contradictory results in the literature presented in the introduction. In our case, zincresistometric sensors were used, and they showed results in good agreement with other techniques, such as corrosion potential monitoring and EIS measurements. Accordingto our results, zinc is able to passivate in a simulated concrete solution and even in a simulated carbonated solution. The corrosion rate was reduced by almost 40 times, duringthe active to passive transition. The zinc remains passive even in simulated concrete solutions contaminated with low levels of chloride ions up to 0.9 wt.%.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20501 - Materials engineering

Result continuities

  • Project

    <a href="/en/project/GA21-11965S" target="_blank" >GA21-11965S: Microstructural investigation and simulation of coupled physical fields in concrete due to electromigration treatments</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Buildings

  • ISSN

    2075-5309

  • e-ISSN

    2075-5309

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    11

  • Pages from-to

    nestránkováno

  • UT code for WoS article

    001430589300001

  • EID of the result in the Scopus database

    2-s2.0-85218636788