Original language description
This work deals with destruction of evaporated halogenated hydrocarbons (dichloromethane, chloroform, tetrachloromethane, freon 113, 1,2-dichloroethane, trichloroethene, tetrachloroethene, tribromomethane and halon H 1011) by combustion with natural gas.The result of the experiment was almost total conversion of organic fixed halogen to HX (X=F, Cl or Br). Only several ppb of volatile organic compounds were detected in flue gas: chloroform, carbon tetrachloride, tetrechlorethylene when chlorinated hydrocarbons were burned, freon 113 when freon 113 was burned and bromoform and bromobenzene when brominated hydrocarbons were burned.. This method was proved to be relatively effective for destruction of halogenated hydrocarbons. The determination of PCDD/F, PCB and PAH in flue gas was carried out for the optimal combustion regime. The total concenration of PCDD/F in flue gas in combustion of tetrachloroethene was 2,2 ng/m3 TEQ.
Czech name
Destrukce halogenovaných organických látek spalováním
Czech description
This work deals with destruction of evaporated halogenated hydrocarbons (dichloromethane, chloroform, tetrachloromethane, freon 113, 1,2-dichloroethane, trichloroethene, tetrachloroethene, tribromomethane and halon H 1011) by combustion with natural gas.The result of the experiment was almost total conversion of organic fixed halogen to HX (X=F, Cl or Br). Only several ppb of volatile organic compounds were detected in flue gas: chloroform, carbon tetrachloride, tetrechlorethylene when chlorinated hydrocarbons were burned, freon 113 when freon 113 was burned and bromoform and bromobenzene when brominated hydrocarbons were burned.. This method was proved to be relatively effective for destruction of halogenated hydrocarbons. The determination of PCDD/F, PCB and PAH in flue gas was carried out for the optimal combustion regime. The total concenration of PCDD/F in flue gas in combustion of tetrachloroethene was 2,2 ng/m3 TEQ.
Classification
Type
D - Article in proceedings
CEP classification
CI - Industrial chemistry and chemical engineering
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2007
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Chisa 2007
ISBN
80-86059-47-2
ISSN
—
e-ISSN
—
Number of pages
14
Pages from-to
1-14
Publisher name
Česká společnost chemického inženýrství
Place of publication
Praha
Event location
—
Event date
—
Type of event by nationality
—
UT code for WoS article
—