Strip-based immunoassay for rapid detection of thiabendazole.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F10%3A00024229" target="_blank" >RIV/60461373:22330/10:00024229 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Strip-based immunoassay for rapid detection of thiabendazole.
Original language description
This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ngmL-1 of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposedtest was as low as 0.08?0.03 ngmL-1 with an IC50 value of 0.60?0.08 ngmL-1 and a linear working range of 0.11?4.13 ngmL-1. Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performan
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GA525%2F07%2F0618" target="_blank" >GA525/07/0618: Immunoassay of pesticides in baby food and fruit juices - development of rapid easy-to-use detection methods</a><br>
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biosensors and Bioelectronics
ISSN
0956-5663
e-ISSN
—
Volume of the periodical
25
Issue of the periodical within the volume
9
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
—
UT code for WoS article
000277930000020
EID of the result in the Scopus database
—