All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Influence of polyaniline on the potentiometric determination of risedronate with ion-selective membranes

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F10%3A00023389" target="_blank" >RIV/60461373:22340/10:00023389 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Influence of polyaniline on the potentiometric determination of risedronate with ion-selective membranes

  • Original language description

    A novel kind of potentiometric sensor for the determination of risedronate in pharmaceutical products is proposed. This potentiometric sensor is comprised of a poly(vinyl chloride) (PVC) membrane based on an anion-exchanger, tridodecylmethylammonium chloride (TDDMACl), and coated with a polyaniline (PANI) layer. The potentiometric response towards a highly hydrated risedronate species was strongly promoted by the presence of the PANI layer. In contrast to uncoated membranes, the PANI-coated membrane exhibited a sensitivity of ?39.9 ? 0.9 mV decade?1 and the detection limit reached 0.45 mg mL?1. The results of the potentiometric analysis of risedronate agreed with those obtained with a validated chromatographic method. The TDDMACl-based membrane coatedwith the PANI layer differentiated 0.94 wt % and 3.44 wt % of a specific contaminant in 1.6 mg mL?1 risedronate.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2010

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical Methods

  • ISSN

    1759-9660

  • e-ISSN

  • Volume of the periodical

    2

  • Issue of the periodical within the volume

    10

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    4

  • Pages from-to

  • UT code for WoS article

    000283959600029

  • EID of the result in the Scopus database