Internal standardisation for arsenic and its species determination using inductively coupled plasma mass spectrometry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F19%3A43916401" target="_blank" >RIV/60461373:22340/19:43916401 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0039914018309494?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0039914018309494?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2018.09.038" target="_blank" >10.1016/j.talanta.2018.09.038</a>
Alternative languages
Result language
angličtina
Original language name
Internal standardisation for arsenic and its species determination using inductively coupled plasma mass spectrometry
Original language description
The signal of As measured by inductively coupled plasma mass spectrometry (ICP-MS) suffers from strong nonspectral interferences due to carbon and alkali metals. The accuracy of the determination of total As using ICP-MS and its species using anion-exchange chromatography coupled to ICP-MS was increased by using selenium as an internal standard. For chromatography, selenium was used in the form of a trimethylselenonium cation, which did not interact with the stationary phase and could be added directly to the mobile phase as the selenite was sufficient for total As determination. Selenium is able to correct non-spectral interferences caused by carbon or sodium up to concentrations of 3000 mg L-1 C and 35 mg L-1 Na, respectively, in the case of total As determination, and up to 3000 mg L-1 C and 3450 mg L-1 Na in the case of speciation analysis. Selenium as an internal standard was tested for the analysis of arsenobetaine in the DORM-2 standard reference material. The results were in good accordance with certified values regardless of NaCl spikes. Also, the results of total As determination in canned fish using a selenium internal standard were not affected by residual carbon in an imperfectly decomposed sample.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
192
Issue of the periodical within the volume
JAN 15 2019
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
86-92
UT code for WoS article
000449443900012
EID of the result in the Scopus database
2-s2.0-85053474299