Internal standardisation for arsenic and its species determination using inductively coupled plasma mass spectrometry

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F19%3A43916401" target="_blank" >RIV/60461373:22340/19:43916401 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0039914018309494?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0039914018309494?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2018.09.038" target="_blank" >10.1016/j.talanta.2018.09.038</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Internal standardisation for arsenic and its species determination using inductively coupled plasma mass spectrometry

  • Original language description

    The signal of As measured by inductively coupled plasma mass spectrometry (ICP-MS) suffers from strong nonspectral interferences due to carbon and alkali metals. The accuracy of the determination of total As using ICP-MS and its species using anion-exchange chromatography coupled to ICP-MS was increased by using selenium as an internal standard. For chromatography, selenium was used in the form of a trimethylselenonium cation, which did not interact with the stationary phase and could be added directly to the mobile phase as the selenite was sufficient for total As determination. Selenium is able to correct non-spectral interferences caused by carbon or sodium up to concentrations of 3000 mg L-1 C and 35 mg L-1 Na, respectively, in the case of total As determination, and up to 3000 mg L-1 C and 3450 mg L-1 Na in the case of speciation analysis. Selenium as an internal standard was tested for the analysis of arsenobetaine in the DORM-2 standard reference material. The results were in good accordance with certified values regardless of NaCl spikes. Also, the results of total As determination in canned fish using a selenium internal standard were not affected by residual carbon in an imperfectly decomposed sample.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    192

  • Issue of the periodical within the volume

    JAN 15 2019

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    7

  • Pages from-to

    86-92

  • UT code for WoS article

    000449443900012

  • EID of the result in the Scopus database

    2-s2.0-85053474299