Bioresorbable scaffold implantation in STEMI patients: 5 years imaging subanalysis of PRAGUE-19 study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F20%3A00001664" target="_blank" >RIV/61383082:_____/20:00001664 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/20:10405040 RIV/00216208:11120/20:43919645 RIV/00064173:_____/20:N0000090
Result on the web
<a href="https://pubmed.ncbi.nlm.nih.gov/32000796/" target="_blank" >https://pubmed.ncbi.nlm.nih.gov/32000796/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12967-020-02230-1" target="_blank" >10.1186/s12967-020-02230-1</a>
Alternative languages
Result language
angličtina
Original language name
Bioresorbable scaffold implantation in STEMI patients: 5 years imaging subanalysis of PRAGUE-19 study
Original language description
Background: Bioresorbable scaffold (BRS) Absorb™ clinical use has been stopped due to higher rate of device thrombosis. Scaffold struts persist longer than 2 years in the vessel wall. Second generation devices are being developed. This study evaluates long-term invasive imaging in STEMI patients. Methods: PRAGUE-19 study is an academic study enrolling consecutive STEMI patients with intention to implant Absorb™ BRS. A total of 83 STEMI patients between December 2012 and March 2014 fulfilled entry criteria. Coronary angiography and optical coherence tomography at 5 year follow-up was performed in 25 patients. Results: Primary combined clinical endpoint (death, myocardial infarction or target vessel revascularization) occurred in 12.6% during the five-year follow-up with overall mortality 6.3%. Definite scaffold thrombosis occurred in 2 patients in the early phase after BRS implantation. Quantitative coronary angiography after 5 years demonstrated low late lumen loss of 0.11 ± 0.35 mm with binary restenosis rate of 0%. Optical coherence tomography demonstrated complete resorption of scaffold struts and mean lumen diameter of 3.25 ± 0.30 and 3.22 ± 0.49 (P = 0.73) at baseline and after 5 years, respectively. Three patients developed small coronary artery aneurysm in the treated segment. Conclusion: Invasive imaging results 5 years after BRS implantation in STEMI showed complete resorption of scaffold struts and stable lumen vessel diameter. Trial registration ISRCTN43696201 (retrospectivelly registred, June 7th, 2019).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Translational Medicine
ISSN
1479-5876
e-ISSN
—
Volume of the periodical
18
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
1-9
UT code for WoS article
000513668500001
EID of the result in the Scopus database
2-s2.0-85078712065