Original language description
New type of silver composite electrode prepared from silver, graphite powder, and methacrylate resin was examined. Electrodes with varied content of silver (10,15,20 %) were used for the determination of 2-nitronaphtalene by differential pulse (DPV) anddirect current voltammetry (DCV). The application of this electrode in differential.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2003
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical Letters. Electrochemistry
ISSN
0003-2719
e-ISSN
—
Volume of the periodical
36
Issue of the periodical within the volume
13
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
2767-2782
UT code for WoS article
—
EID of the result in the Scopus database
—