Z-Scan Fluorescence Correlation Spectroscopy as a Tool for Diffusion Measurements in Planar Lipid Membranes

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F14%3A00506914" target="_blank" >RIV/61388955:_____/14:00506914 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/978-1-62703-649-8_28" target="_blank" >http://dx.doi.org/10.1007/978-1-62703-649-8_28</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-1-62703-649-8_28" target="_blank" >10.1007/978-1-62703-649-8_28</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Z-Scan Fluorescence Correlation Spectroscopy as a Tool for Diffusion Measurements in Planar Lipid Membranes

  • Original language description

    Studies of lateral diffusion are used for the characterization of the dynamics of biological membranes. One of the techniques that can be used for this purpose is fluorescence correlation spectroscopy (FCS), which belongs to the single-molecule techniques. Unfortunately, FCS measurements, when performed in planar lipid systems, are associated with a few sources of inaccuracy in the determination of the lateral diffusion coefficient. The main problems are related to the imperfect positioning of the laser focus relative to the plane of the sample. Another source of inaccuracy is the requirement for external calibration of the detection volume size. This protocol introduces a calibration-free method called Z-scan fluorescence correlation spectroscopy (Z-scan FCS), which is based on the determination of the diffusion time and particle number in steps along the optical (z-) axis by sequential FCS measurements. Z-scan FCS could be employed for diffusion measurements in planar membrane model systems-supported phospholipid bilayers (SPBs) and giant unilamellar vesicles (GUVs) and also in biological membranes. A result from measurements in SPBs is also presented in the protocol as a principle example of the Z-scan technique.

  • Czech name

  • Czech description

Classification

  • Type

    C - Chapter in a specialist book

  • CEP classification

  • OECD FORD branch

    10403 - Physical chemistry

Result continuities

  • Project

    <a href="/en/project/GAP208%2F10%2F0376" target="_blank" >GAP208/10/0376: Interaction of antibacterial peptides with the model membranes and possibility of the prediction of their biological activity</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Book/collection name

    FLUORESCENCE SPECTROSCOPY AND MICROSCOPY: METHODS AND PROTOCOLS

  • ISBN

    978-1-62703-648-1

  • Number of pages of the result

    18

  • Pages from-to

    "Roč. 1076 (2014)"

  • Number of pages of the book

    817

  • Publisher name

    HUMANA PRESS INC

  • Place of publication

    Totowa

  • UT code for WoS chapter

    000328374800029