All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Pitfalls in the analysis of volatile breath biomarkers: suggested solutions and SIFT-MS quantification of single metabolites

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F15%3A00452362" target="_blank" >RIV/61388955:_____/15:00452362 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/1752-7155/9/2/022001" target="_blank" >http://dx.doi.org/10.1088/1752-7155/9/2/022001</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1752-7155/9/2/022001" target="_blank" >10.1088/1752-7155/9/2/022001</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Pitfalls in the analysis of volatile breath biomarkers: suggested solutions and SIFT-MS quantification of single metabolites

  • Original language description

    The experimental challenges presented by the analysis of trace volatile organic compounds (VOCs) in exhaled breath with the objective of identifying reliable biomarkers are brought into focus. It is stressed that positive identification and accurate quantification of the VOCs are imperative if they are to be considered as discreet biomarkers. Breath sampling procedures are discussed and it is suggested that for accurate quantification on-line real time sampling and analysis is desirable. Whilst recognizing such real time analysis is not always possible and sample collection is often required, objective recognition of the pitfalls involved in this is essential. It is also emphasized that mouth-exhaled breath is always contaminated to some degree by orally generated compounds and so, when possible, analysis of nose-exhaled breath should be performed. Some difficulties in breath analysis are mitigated by the choice of analytical instrumentation used, but no single instrument can provide s

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CF - Physical chemistry and theoretical chemistry

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Breath Research

  • ISSN

    1752-7155

  • e-ISSN

  • Volume of the periodical

    9

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    11

  • Pages from-to

  • UT code for WoS article

    000355656200002

  • EID of the result in the Scopus database

    2-s2.0-84930625565