Status of selected ion flow tube MS: accomplishments and challenges in breath analysis and other areas

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F16%3A00462213" target="_blank" >RIV/61388955:_____/16:00462213 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.4155/bio-2016-0038" target="_blank" >http://dx.doi.org/10.4155/bio-2016-0038</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.4155/bio-2016-0038" target="_blank" >10.4155/bio-2016-0038</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Status of selected ion flow tube MS: accomplishments and challenges in breath analysis and other areas

  • Original language description

    This article reflects our observations of recent accomplishments made using selected ion flow tube MS (SIFT-MS). Only brief descriptions are given of SIFT-MS as an analytical method and of the recent extensions to the underpinning analytical ion chemistry required to realize more robust analyses. The challenge of breath analysis is given special attention because, when achieved, it renders analysis of other air media relatively straightforward. Brief overviews are given of recent SIFT-MS breath analyses by leading research groups, noting the desirability of detection and quantification of single volatile biomarkers rather than reliance on statistical analyses, if breath analysis is to be accepted into clinical practice. A strengths, weaknesses, opportunities and threats’ analysis of SIFT-MS is made, which should help to increase its utility for trace gas analysis.n

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CF - Physical chemistry and theoretical chemistry

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GA13-28882S" target="_blank" >GA13-28882S: Excitation, separation and fragmentation of ions by drift fields in SIFT-MS for immediate selective trace gas quantification</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Bioanalysis

  • ISSN

    1757-6180

  • e-ISSN

  • Volume of the periodical

    8

  • Issue of the periodical within the volume

    11

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    19

  • Pages from-to

    1183-1201

  • UT code for WoS article

    000376676900006

  • EID of the result in the Scopus database

    2-s2.0-84971493100